EPS Switching power supply

4303 series

EPS-4303 is a power supply with battery charging.It has short circuit and over load protection,high efficency,long life and high reliablity.Seamless transformation of power failure.

Product Display

Product Specification

MODEL4303-124303-24
CH1CH2CH1CH2
OutputDC Voltage13.5V13.5V27V27V
Rated Current3A/1.5A/
Current Range0~3A/0~1.5A/
Charging Voltage/13.5V/27V
Charge Current/0~0.8A/0~0.8A
Rated Power40.5W/40.5W/
Ripple & Noise Max(Note2)120mVp-p/20mVp-p/
Voltage Adj. Range±10%/±10%/
Voltage Tolerance(Note 3)±5%/±5%/
Line Regulation(Note 4)±0.5%/±0.5%/
Load Regulation(Note 5)±1.0%/±1.0%/
Setup/Rise Time500ms, 50ms/220Vac (Full load)
Hold up time(Typ.)50ms/220Vac (Full load)
InputVoltage Range100~240Vac
Frequency Range50/60Hz
Efficiency(Typ.)82%
Ac Current(Typ.)0.8A/220Vac
Inrush Current(Typ.)40A
Leakage Current(Typ.)3.5mA
ProtectionOver Load protection105%~150%
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage protection78%~90%
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Shoot protectionProtection mode: the device up mode, after removing the abnormal conditions can be automatically restored
FeaturesFeatures IntroductionBattery floating long-line, high charging efficiency, battery saturation can be up to 90%
Stoped to prevent overcharging, effectively extending the battery life
Mains / battery automatic switchover time is very short, without staff on duty
Can directly start the EPS batteries to meet emergency needs of users
EnvironmentWorking Temp-10℃~60℃
Working Humidity20~90%RH, non-condensing
Storage Temp/Humidity-20℃~75℃  10~98%RH,non-condensing
Temp. Coefficient±0.03%/℃(0~50℃)
Vibration10Min/1 cycle, period for 60min,each along X,Y,Z axes
Safety & EMC(Note 7)Safety Standards(Note 6)GB4943, EN60950
Withstand VoltageI/P-O/P: 2.5KVAC  I/P-FG: 1.5KVAC O/P-SFG: 1.5KVAC
Isolation ResistanceI/P-O/P I/P-FG O/P-FG: 100M Ohms/500VDC/25℃/70%RH
EMI Conduction RadiationCompliance to: EN55022, EN61000-3-2,3, FCC part15,GB9254 class B,GB17625.1
EMS ImmunityCompliance to: EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OthersMBTF≥100000h.
Dimension/Packing110*78*38m(L*W*H) /0.25KG;100pcs/25Kg
Note1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf &47uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.Load regulation measurement: from 0% to rated load of 100%
6.In accordance with the requirements of GB4943.1 power applies only to an altitude of 2000 meters in the following areas and non-tropical climate conditions for Safe use.
7.The power supply is considered part of the system components, to be with terminal equipment related to electromagnetic compatibility Relevant confirmation..

Design Drawing

Production Process

Application

Product Message

Ask for free custom survice now!

Related Products

______

Chat Online 编辑模式下无法使用
Chat Online inputting...