Model | SY-A9/12 | ||||||
Output | DC Voltage | 12V | 12V | 12V | |||
Rated Current | 1A | 2A | 3A | ||||
Current Range | 0~1A | 0~2A | 0~3A | ||||
Rated Power | 12W | 24W | 36W | ||||
Ripple & Noise Max Note 3 | 80mVp-p | 80mVp-p | 80mVp-p | ||||
Voltage Tolerance Note 3 | ±5% | ±5% | ±5% | ||||
Line Regulation(Note 4) | ±1% | ±1% | ±1% | ||||
Load Regulation(Note 5) | ±2% | ±2% | ±2% | ||||
Setup, Rise Time | 500ms 200ms 30ms (Full load)30 | ||||||
Input | AC plug | AC Plug-UK | AC Plug-CN | AC Plug-EN | AC Plug-US | ||
Voltage Range | 100Vac~240Vac110VAC~240AVC,130VDC~370ADC | ||||||
Frequency Range | 50/60Hz | ||||||
Efficiency(Typ.) | 85% | 86% | 86% | ||||
Ac Current(Typ.) | 0.38A/200Vac | ||||||
Inrush Current(Typ.) | 35A/220Vac | ||||||
Leakage Current(Typ.) | <0.35mA/220Vac | ||||||
Protection | Over Load | Rated output power: 110%~240% | |||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
Over Voltage | Rated output Voltage:115%~135% | ||||||
Protection mode: diode clamp | |||||||
Over Temp(Note 5) | Crystal internal contact temperature exceeds 140 ℃, start over temperature protection. | ||||||
Protection mode: turn off the output voltage, the temperature drops automatically resume | |||||||
Environment | Working Temp | -0℃~50℃(Refer to "Derating curve ") | |||||
Working Humidity | 0~90%RH, non-condensing | ||||||
Storage Temp/Humidity | -10℃~75℃ 10~98%RH, non-condensing | ||||||
Temp. Coefficient | ±0.03%/℃(0~50℃) | ||||||
Vibration | 10Min/1 cycle, period for 60min,each along X,Y,Z axes | ||||||
Safety & EMC Note 7 | Safety Standards | GB4943, EN60950 | |||||
Withstand Voltage | I/P-O/P: 2KVac | ||||||
Isolation Resistance | I/P-O/P: 100M Ohms/500VDC/25℃/70%RH | ||||||
EMI Conduction Radiation | Compliance to: EN55022, EN61000-3-2,3, FCC part15,GB9254 class B,GB17625.1 | ||||||
EMS Immunity | Compliance to: EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A | ||||||
Others | Life | 2 years: 100% load, 30, 8 hours / day | |||||
MTBF | ≥1415.6Khrs | ||||||
Dimension | 154*78*42mm(L*W*H) | ||||||
Packing | 0.2Kg 100pcs/20Kg | ||||||
Connector | Plug/Wiring | For second pages, other models can be customized according to customer requirements. | |||||
Note | 1.If no special instructions are specified, all the specifications are measured at the input of 230VAC, the rated load, the ambient temperature of 25℃. 2.Ripple and noise measuring method: using a 12" twisted pair, at the same time terminal to parallel 0.1uF and 47uF capacitor, in the 20MHZ bandwidth measurement. 3.Curacy: contains setting error, linear adjustment rate and load adjustment rate. 4.Linear adjust rate measurement: at rated load, from a low voltage to a high voltage test. 5.Load adjustment rate measurement method: from 20% to 100% 6.Overtemperature protection is determined by the function of the control IC. |
Model | SY-A9/24 | ||||
Output | DC Voltage | 24V | 24V | ||
Rated Current | 1A | 2A | |||
Current Range | 0~1A | 0~2A | |||
Rated Power | 24W | 48W | |||
Ripple & Noise Max Note 3 | 80mVp-p | 80mVp-p | |||
Voltage Tolerance Note 3 | ±5% | ±5% | |||
Line Regulation(Note 4) | ±1% | ±1% | |||
Load Regulation(Note 5) | ±2% | ±2% | |||
Setup/Rise Time | 500ms 200ms 30ms (Full load) 30 | ||||
Input | AC plug | AC Plug-UK | AC Plug-CN | AC Plug-EN | AC Plug-US |
Voltage Range | 100Vac~240Vac 110VAC~240AVC,130VDC~370ADC | ||||
Frequency Range | 50/60Hz | ||||
Efficiency(Typ.) | 85% | 86% | |||
Ac Current(Typ.) | 0.4A/200Vac | ||||
Inrush Current(Typ.) | 35A/220Vac | ||||
Leakage Current(Typ.) | <0.35mA/220Vac |