SE-10W
|
MODEL | AD-S0520AA | AD-S0910AA | AD-S1208AA | AD-S15066AA | AD-S24041AA | AD-S4802AA |
Output | DC Voltage | 5V | 9V | 12V | 15V | 24V | 48V |
Rated Current | 2A | 1A | 0.8A | 0.66A | 0.41A | 0.2A |
Current Range | 0~2A | 0~1A | 0~1A | 0~0.8A | 0~1A | 0~0.5A |
Rated Power | 24W | 24.03W | 24W | 24W | 24W | 24W |
Ripple & Noise Max(Note2) | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p |
Voltage Adj. Range | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
Voltage Tolerance(Note 3) | ±7% | ±7% | ±6% | ±5% | ±5% | ±5% |
Line Regulation(Note 4) | ±0.5% | ±0.5% | ±1% | ±1% | ±1% | ±1% |
Load Regulation(Note 5) | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Setup/Rise Time | 1000ms,30ms/220Vac (Full load) |
Hold up time(Typ.) | 100ms/220Vac (Full load) |
Input | Voltage Range | 100~240Vac |
Frequency Range | 50/60Hz |
Efficiency(Typ.) | 80% | 80% | 85% | 85% | 80% | 80% |
Ac Current(Typ.) | 0.1A/220Vac |
Inrush Current(Typ.) | Cold Start: 50A/220Vac |
Leakage Current(Typ.) | 3mA |
Protection | Over load protection | 110%~135% |
Protection type: Hiccup mode,recovers automatically after fault condition is removed |
Over Voltage protection | 115%~150% |
Protection type: Hiccup mode,recovers automatically after fault condition is removed |
Over-temperature protection | Protected Mode: crystal internal contact temperature exceeds 140℃, turn off the output, when the temperature returns to normal automatic recovery |
Environment | Working Temp | -10℃~60℃(Refer to "derating curve ") |
Working Humidity | 20~90%RH, non-condensing |
Storage Temp/Humidity | -30℃~75℃ 10~98%RH, non-condensing |
Temp Coefficient | ±0.03%℃(0~50℃)(+5V) |
Vibration | 10Min/1 cycle,period for 60min, each along X, Y, Z axes |
Safety & EMC(Note 7) | Safety Standards Note 6 | GB4943, EN60950 |
Withstand Voltage | I/P-O/P: 2.5KVAC I/P-FG: 1.5KVAC O/P-FG: 1.5KVAC |
Isolation Resistance | I/P-O/P I/P-FG O/P-FG: 100M Ohms/500VDC/25℃/70%RH |
EMI Conduction Radiation | Compliance to: EN55022, EN61000-3-2, 3. FCC part15, GB9254 class B, GB17625.1 |
EMS Immunity | Compliance to: EN61000-4-2, 3, 4, 5, 6, 8, 11, light industry level, criteria A |
Others | MBTF | ≥10000h. |
Dimension/Packing | 70*40*31mm(L*W*H) /0.1KG;500pcs/50Kg |
Note | 1.All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25℃ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf &47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation measurement: from 0% to rated load of 100%. 6.In accordance with the requirements of GB4943.1 power applies only to an altitude of 2000 meters in the following areas and non-tropical climate conditions for safe use. 7.The power supply is considered part of the system components, to be with terminal equipment related to electromagnetic compatibility Relevant confirmation. |